PANEL CRAFT

The PanelCraft panel system technology has been tested and certified by independent testing agencies and laboratories and achieved the loads and listings shown below.

Underwriters Laboratories Inc. Construction No.506, 506A, 506B
PanelCraft Roof with TripleLok and QuadLok Seam
UL
Listing
Panel
Width
Panel
Gauge
Seam
Type
Purlin
Gauge
Purlin
Spacing

UL-90 16"& 18" 24 ga. All Seam Types 16 ga. 5'0"
 

Factory Mutual 4471 Uplift Test Results
PanelCraft Roof with TripleLok and QuadLok Seam
FM
Listing
Panel
Width
Panel
Gauge
Purline
Depth
Purlin
Gauge
Purlin
Spacing
 
1-90 16"& 18" 24 ga. 8" 16 ga. 5'0"  
1-165 16"& 18" 22 ga. 8" 16 ga. 2'6"  

ASTM E 1592 Uplift Test Results
PanelCraft Roof with TripleLok Seam
Purlin
Spacing
Panel
Width
Panel
Gauge
Design Load
CEGS (sf=1.65°)
2'6" 16" 24 ga. 79.4
5'0" 16" 24 ga. 48.1
7'6" 16" 24 ga. 28.8
2'6" 18" 24 ga. 82.7
5'0" 18" 24 ga. 44.9
7'6" 18" 24 ga. 31.5

ASTM E 1592 Uplift Test Results
PanelCraft Roof with QuadLok Seam
Purline
Spacing
Panel
Width
Panel
Gauge
Design Load
CEGS (sf=1.65°)
2'6" 16" 24 ga. 97.7
5'0" 16" 24 ga. 63.0
7'6" 16" 24 ga. 45.7
2'6" 18" 24 ga. 94.5
5'0" 18" 24 ga. 56.7
7'6" 18" 24 ga. 37.8

ASTM E 1680 Air Infiltration all seams 16" wide panels = .005 CFM/sq.ft
ASTEM E 1646 Water Leakage all seams 16" wide panels=None at 12 psf

*Design Load =(Mean Ultimate Load/Safety Factor)based on U.S. Corps of Engineers CEGS07416

PanelCraft roof system and its components are covered by US Patent numbers 5,692,352 - 5,737,894 - 6301,853 B1 and other patents pending.


 
     
 

Contact BRS

P - (405) 330-8803
E - sales@brsusa.com
A - P.O. Box 2526
      Edmond, Oklahoma  73083