TS324

The TS-324 panel system technology has been tested and certified by independent testing agencies and laboratories and achieved the loads and listings shown below.

Underwriters Laboratories Inc. Construction No.556, 556A, 556B
TS-324 roof with RollLok, TripleLok and QuadLok Seam
UL
Listing
Panel
Width
Panel
Gauge
Seam
Type
Purlin
Gauge
Purlin
Spacing
 
UL-60 24" 24 ga. All Seam Types 16 ga. 5'0"  
UL-90 24" 24 ga. All Seam Types 16 ga. 5'0"  

Factory Mutual 4477 Uplift Test Results
TS-324 roof with TripleLok and QuadLok Seam
FM
Listing
Panel
Width
Panel
Gauge
Purline
Depth
Purlin
Gauge
Purlin
Spacing
 
1-60 24" 24 ga. 8" 16 ga. 5'0"  
1-90 24" 24 ga. 8" 16 ga. 4'0"  

ASTM E 1592 Uplift Test Results
TS-324 roof with RollLok Seam
Purlin
Spacing
Panel
Width
Panel
Gauge
Design Load
AISI CF00-1 (sf=1.724°)
 
2'6" 24" 24 ga. 6.2  
5'0" 24" 24 ga. 32.1  

ASTM E 1592 Uplift Test Results
TS-324 roof with TripleLok Seam
Purline
Spacing
Panel
Width
Panel
Gauge
Design Load
CEGS (SF=1.65°)
 
2'6" 24" 24 ga. 83.0  
5'0" 24" 24 ga. 56.2  

ASTM E 1592 Uplift Test Results
TS-324 roof with QuadLok Seam
Purline
Spacing
Panel
Width
Panel
Gauge
Design Load
CEGS (SF=1.65°)
 
2'6" 24" 24 ga. 120.3  
5'0" 24" 24 ga. 64.2  

ASTM E 1680 Air Infiltration all seams 24" wide panels = .005 CFM/sq.ft
ASTEM E 1646 Water Leakage all seams 24" wide panels=None at 12 psf

*Design Load =(Mean Ultimate Load/sf) x 1.33 when allow by building code